Availability: Discontinued
Sommer Tricone MkII Unbalanced Cable (Green) (Part number: 300-0024)
SOMMER SESSION Mk 2 INSTRUMENT CABLE Where unbalanced single conductor cable is to be used in unpredictable situations then this Session cable is a major contender. The outer diameter is 6.0 mm because the inner conductor is surrounded by a very low loss foamed dielectric to minimise high frequency loss in high impedance circuits. The dielectric is then surrounded by a carbonised plastic antistatic tube which stops crackles when the cable is moved. Again, high impedance circuits would suffer without this antistatic tube. Dense spirally wound copper strands form a 100% shield against interference and helps maintain a supple cable. Still supple down to -30 C.
Advantages:
- Very robust due to the large wire cross-section and fine Cu single litz wires
- Good electrical values due to the Skin PE insulation
- 100 % protection by dual shielding (helical copper mesh screen + conductive carbon screen)
- High number of bending cycles
Application:
- Dependable cable for live applications (guitar and keyboard)
- Economy-priced Line-in or Patchcable for the Homerecorder
Sold by the metre. Four colours: Black Code 546-090
Red Code 546-820
Blue Code 546-100
Green Code 546-830
Specifications:
Name | Tricone® MKII |
---|---|
Properties | OFC oxygen free copper |
Properties | Analog |
Application area | Mobile outdoor / indoor |
Application area | Stage / live |
Application area | Installation |
Application | Instrument Cable |
Colour | green |
Colour detailed | green |
Signal transmission | asymmetrical |
Construction | LI2Y(LS)DY1x0,22mm² |
Jacket material | PVC |
Jacket Ø [mm] | 5,90 |
Number of Channels (audio) | 1 |
Inner conductor (audio) | 1 |
Inner conductor (audio) [mm²] | 0,22 |
Inner conductor Ø (audio) [mm] | 0,53 |
AWG (audio) | 24 |
Shielding | Copper braided shielding + semiconductor |
Copper strands (audio) | 28 |
Copper strand Ø (audio) [mm] | 0,10 |
Conductor insulation material | Foam / Skin-PE |
Conductor insulation Ø [mm] | 1,80 |
Weight per 1 m [g] | 42 |
Fire load per m [kWh] | 0,26 |
Style variant | round |
Shielding factor [%] | 100 |
Packing | 100 m spool |
Packing | 500 m spool |
Temperature min. [°C] | -25 |
Temperature max. [°C] | 60 |
Width [mm] | 5,9 |
Height [mm] | 5,9 |
Capac. cond./shield. per 1 m (audio) [pF] | 85 |
Capacity wire/electic screen at 1 ft. (audio) [pF] | 25,908 |
Insulation resist. per 1 km [GΩ] | 1 |
Insulation resist. per 1000 feet [GΩ] | 0,3048 |
Insulation resist. per 1 km (audio) [GΩ] | 1 |
Insulation resist. per 1000 feet (audio) [GΩ] | 0,3048 |
Conductor resistance per 1 km [Ω] | 90 |
Conductor resistance per 1000 ft. [Ω] | 27,432 |
EAN | 4049371002172 |
Fca |
Choose Your Cable Length | 1m |
---|